<LOGO>
FM Transmitter Measurement Report
Created: 2025-01-20 09-16-59
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
92.50 MHz 3/5, 46 dBuV ISKELMA
Pilot RDS Phase Difference
7.2 kHz 0 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
15 kHz 19 kHz 2675 0,1121
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
4,6 dBr 6,08 dBr 7,1 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"ISKELMA " 62AD 9 (Varied) 1 0 0 0 --:--
RT
-
AF EON
89.4, 92.5, 100.1, 107.7 MHz -
FM Scope Max at: 19 kHz MIN: 15 kHz % above 76 kHz: 0,1121 Acquired: 2025/01/20 9.15.56 Total samples: 2675 Equivalent time: 0:02:13 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 50 100 150
FM Scope MAX: 7,1 dBr MIN: 4,6 dBr AVE: 6,08 dBr % above 12,2 dBr: 0,0 Last value: 6,0 dBr (2025/01/20 9.15.56) 09.02 09.04 09.06 09.08 09.10 09.12 09.14 0 2 4 6 8 Pm [dBr]